• collapse_already@lemmy.ml
    link
    fedilink
    English
    arrow-up
    3
    ·
    2 hours ago

    Yeah, the protocol itself is pretty robust. The cable I had didn’t have enough noise immunity for the dirty power the building had in India (afternoon brown outs when the voltage dipped when the air conditioners ran). The Faraday cage that I made around the cable helped with the noise and also (and I believe more crucially though I had no scope to confirm) gave the two boards a common ground. I had a little trouble with before I left, but it didn’t work at all in India until I modded it. Made the hardware engineer buy me a beer when I got back.