• cynar@lemmy.world
    link
    fedilink
    English
    arrow-up
    9
    ·
    18 hours ago

    I had a chat about this with a friend who works for the national grid (UK).

    Apparently the problem is keeping the grid balanced and stable. Basically, the grid struggles to react fast, so they plan ahead. Things like large scale solar can provide predictions on output. Home solar can’t.

    When clouds pass over an area it can cause slumps and surges in the local grid. The more home solar, the worse it gets. The current grid is designed to work top down, with predictable changes in demand. It needs upgrading to deal with large scale bidirectional flows.

    The plug in units are (potentially) even more ropey. If used properly, they are no worse than normal home solar. Unfortunately, being cheaper, there are worries over the microinverters not shutting down. Either due to the manufacturer cheaping out, or turning on an “off grid” mode.

    There are also worries about overloading household circuits. Back feeding bypasses the household circuit breakers and RCDs. They could overload wall wiring and cause fires, or stop an RCD tripping, allowing for a person to be shocked.

    I don’t know how much this would apply to the American Grid, but I would imagine it would be worse. Your grid is older and larger. You also use 120VAC which makes the current overload issue a lot worse.

    • partial_accumen@lemmy.world
      link
      fedilink
      English
      arrow-up
      4
      ·
      edit-2
      15 hours ago

      You also use 120VAC which makes the current overload issue a lot worse.

      Voltage inside of residences is 120v AC, but its 240v thats delivered to each house. I think a bigger difference is that in the USA that 240v AC is single phase where I believe (Germany included) many nations in the EU are 3 phase.

      The USA does have 3 phase power for most commercial applications though.

      • cynar@lemmy.world
        link
        fedilink
        English
        arrow-up
        2
        ·
        12 hours ago

        It’s worth noting that this is talking about plug in solar, so would be at standard mains voltage.

        1kw would be around 4A in Europe, but 8A in the USA. Also, since resistive losses scale with I^2 that’s 4x the heat dumped in the walls.

        At least in the UK, they tend to run 3 phase to a road, but only a single phase goes into a given house. You need to get a special hook up to get 3 phase to a domestic premise, and they don’t like doing it.

        • partial_accumen@lemmy.world
          link
          fedilink
          English
          arrow-up
          3
          ·
          11 hours ago

          It’s worth noting that this is talking about plug in solar, so would be at standard mains voltage.

          Thats fair.

          At least in the UK, they tend to run 3 phase to a road, but only a single phase goes into a given house. You need to get a special hook up to get 3 phase to a domestic premise, and they don’t like doing it.

          TIL about the UK electrical system. Thanks!

          I’m at the edge of my knowledge but that sounds like it matches the USA system (for the number of phases).